Frequently asked questions
We have created a list of frequently asked question assist
you with technical information, look through the list
if you don't find the answer to your question, don't hesitate to give us a call
were here to help.
Software and computer related
Q. I get a message "key not found" when the program
starts, what do I do?
A. Check to see that the key did not fall out of the serial port,
make sure the serial port is not been disabled,
try another com port.
Q. The program runs but all the instruments a dead?
A. The problem is the software and or computer fails to see the PLC.
Try turning the power to the PLC off and on
and reboot the computer this usually works, if not look at
the computers IP address it should read 198.162.2.20
then check configurator page 5 of 8 and verify that
configurator see the same IP address.
Q. Can I install the software on more than one
computer?
A. Yes, but the software will not run without the software key.
Q. My computer broke and I bought another one and I
don't have any backup calibration files, do I
have to do calibration all over again?
A. Maybe not. The person or company that installed the system should have
backup ini files of your system and/or
the four REP's may have copies of them. Another way is
to take the hard drive from the defective computer
assuming the hard drive is was not the problem install it in
the new computer, setup your IP address in the new
computer and now write the backup in files to a CD label the
CD so this does not happen again. And your on your
way.
Q. Can I setup my laptop/another computer as a
backup system?
A. Yes, Install FT NavVision, setup your IP address, copy your
configuration files to the backup computers FT NavVision
directory, plug the ethernet cable over to the backup
computer, install the software key in the backup computers
serial port and your finished.
Q. I read engine data directly from the engines but
I have all dead instruments on the engine page?
A. If the needle in the instruments are dark gray in color there is
no data coming in the com port, verify in configurator
that the correct protocol has been assign to the com port
that is assigned to the engine.
Q. I downloaded a newer version and things don't
work or have changed what do I do?
A. De-install the newer version, install your original version and
contact tech support.
Sensor related
Q. My Ex: fuel gauge instrument shows full/empty all
the time?
A. Ohm out sender if resistive, check sender supply voltage, check
connection, contact tech support for further advice.
Q. If I have to replace a sender do I have to
recalibrate the settings?
A. No as long as you don't change to a sensor with different
electrical specs.
Q. Can I add another item to monitor to the system?
A. Yes, contact tech support for a procedure on what is envolved.
Q. Do I have to do periodic re-calibration to
sensors?
A. No.
Q. Why is my instrument not reading accurately?
A. The sensor may have went out of spec or the configurator
calibration values may have been altered.
Warranty related
Q. I lost my software key (dongle) how do I get a
replacement?
A. There is no provisions for a replacement key if it is lost or stolen. You
must purchase the licenses again.
Q. I ordered the wrong license module, can I get a
credit/refund?
A. No, all software sales are final, once a license # is given to an end user we
have no way of taking it back.
Q. Can I transfer my licenses to another individual?
A. Yes, the licenses are not assigned to an end user they are
assigned to a software key.
Q. If my software key is defective can I get a
replacement?
A. Yes, you must return the defective key to Free Technics BV for a
replacement.
Q. I lost my software CD can I get a replacement CD?
A. Yes, all we must know is what version are you currently running.